PGD Load cell

PGD Load cell, 2t~50t, self restoring rocker pin

Features:
  • Stainless steel
  • Protection class IP68 as hermeticallysealed
  • High accuracy
  • Excellent durability
  • Low self-weight and easy installation
  • Optionally available with service temperature range up to 200°C (413°F).

Specification

  • Rated capacity t 2,5,10 20,30,50
  • Rated output mV/V 1 ± 0.002
  • Non repeatbility %R.C. ≤0.01
  • Hysteresis %R.C. ≤0.02 ≤0.03
  • Non linearity %R.C. ≤0.02 ≤0.03
  • Creep(30min) %R.C. ≤0.02 ≤0.03
  • Zero balance %R.C. ≤1
  • Temp. Compensated range °C -10~+40
  • Operating temp. Range °C -20~+65
  • Temp. coefficient on output %Load/ °C ≤0.002
  • Temp. coefficient on zero balance %R.C./ °C ≤0.002
  • Input resistance Ω695 ± 7
  • Output resistance Ω600 ± 2
  • Insulation resistance M5000(50V DC)
  • Recommended voltage V(DC/AC) 5~15
  • Max. excit. voltage V(DC/AC) 20
  • Safe overload %R.C. 200
  • Ultimated overload %R.C. 500
  • Protection class IP68
  • Cable length m 10

Download PGD load celll Special Features