IL Load cell

IL Load cell, 150kg~2t, bending beam

Features:
  • OIML R60 C3 approved
  • Single point load cell
  • High accuracy
  • Excellent durability
  • Protection class IP67
  • Off center load compensated
  • Alloy steel with nickel plated

Specification

  • Rated capacity kg 150,250,500,1000,2000
  • Rated output mV/V 2 ± 0.002
  • Non repeatbility %R.C. ≤0.01
  • Hysteresis %R.C. ≤0.02
  • Non linearity %R.C. ≤0.02
  • Creep(30min) %R.C. ≤0.02
  • Zero balance %R.C. ≤1
  • Temp. Compensated range °C -10~+40
  • Operating temp. Range °C -20~+60
  • Temp. coefficient on output %Load/ °C ≤0.002
  • Temp. coefficient on zero balance %R.C./ °C ≤0.002
  • Input resistance Ω387 ± 4
  • Output resistance Ω350 ± 1
  • Insulation resistance M ≥5000 (50V DC)
  • Recommended voltage V(DC/AC) 5~15
  • Max. excit. voltage V(DC/AC) 20
  • Safe overload %R.C. 150
  • Ultimated overload %R.C. 300
  • Protection class IP67
  • Max platform size mm 800x800(I L-2000: 1000x1000)
  • Cable length m 2.5

    Download IL Load cell Special Features